Medior Product Design Engineer at PackBack, since Mar 2026.
Concept engineering
NFC activation spot
RF modelling
PackBack × Burger King
0 scans
for the crew: setting the drink down is the activation
23 mm
read edge, so only the cup on the spot is read
2 spots
per restaurant, counter and drive-thru, one cable each
€285 to €485
hardware per restaurant, planning range
Product design problem
58%
of fast-food transactions include a drink (2024 QSR). Every one is a chance for a missed activation.
Model with stated assumptions: about 4 s per scan, 1 minute to fix a rejected cup, the order screen catches 9 in 10 forgotten cups, 1 in 1,000 cups on the spot not read. The pilot measures the real rates.
Staff forgets to scan the cup
Customer finishes the drink
Return machine rejects the cup
Customer walks back to the counter
Paid at the till
Taken from the clean stack
Filled at the drink station
Set down for the hand-out
Returned at the machine
Read where the drink is set down for the hand-out
Every reusable drink passes it after payment: dine-in, takeaway and drive-thru.
Make the read a side effect of serving
Setting a drink down is a move the crew already make. A scan is a move they can forget.
Read only the cup that is set down
A zone of a few centimetres. Clean stock and the next order stay outside it.
Keep electronics out of what gets washed or carried away
Trays go through the tray wash and out to the tables. A reader in every tray needs batteries, charging and sealing.
Show the result where the crew already look
A light at the spot and on the tray stop, and a short beep.
Let the order system decide
A read only counts when an open order on that lane has a reusable cup on it.
Product research
RECUP at Burger King Germany
No tag. A deposit cup that any partner accepts
Paying the €1 deposit at the till
Staff handle the deposit at both ends
Cuploop, Estonia
Passive UHF tag with a unique ID
Staff scan the cup with a handheld reader and link it to the customer’s bank card
One extra scan per cup at the counter
Delete Cups, UK
RFID tag in the cup
The barista scans the cup when taking payment
Depends on staff remembering the scan
TOMRA event cups
Embedded RFID chip
The chip is coupled with the payment record at purchase
Needs an integrated till and reader
Bold Reuse, Portland stadiums
UHF inlay rated for 1,000 industrial washes
Read in bulk by fixed readers at the wash hub
Tracks circulation, not the individual sale
Every tagged system I found still links the cup to the sale by hand at the counter. That manual step is exactly the one that gets missed at PackBack, so the concept has to make it happen as a side effect of serving.
What the physics allows
NFC, 13.56 MHz
Leads to concepts A and C
Range
Centimetres. With a 60 mm coil a small tag is read up to 11.5 mm above the surface and 23 mm off centre.
Full drinks
The drink barely absorbs the field: skin depth 14 to 61 cm for drinks of 0.05 to 1 S/m. A 4 mm gap keeps it from detuning the tag.
Metal
Steel 2 mm under the coil cuts the field at the tag from 5.8 to 0.8 A/m. A ferrite sheet and tuning in place bring it back.
Reads
One cup at a time, by setting it down. Four coils read a carrier of four.
UHF RFID, 865 to 868 MHz
Leads to concept B
Range
Metres. At the EU limit of 2 W e.r.p. a small tag on an empty cup is read about 21 m away in free space.
Full drinks
Water absorbs and detunes. I assumed a full cup 9 dB below an empty one, to be measured.
Stray reads
Tuned to read a full cup between towers 400 mm apart, a fence still reads an empty cup up to about a metre away.
Reads
Many cups at once, with no line of sight.
Sources: RFID Journal (Cuploop, Delete Cups), Packaging Europe (Burger King and RECUP), Packaging World (Bold Reuse with Avery Dennison), TOMRA, ISO/IEC 14443-2:2016, CEPT ERC/REC 70-03, Impinj M800 product brief, NXP NTAG 213 data sheet. Ranges and losses come from the models further down.
Three concepts
Solution A
The cup activates the moment it is placed on the marked tray spot.

Solution B
The cup activates as it passes between two reader towers during handover.

Solution C
The cup activates when it is set down at the hand-out, in a dish or in the ring of a passive tray.

Solution C
No scan and no handheld for the crew
Trays stay passive and go through the tray wash as today
One cable per spot: power and data over PoE
Works for trays, bags and drive-thru carriers
Before
Worker must remember to scan the cup
After
Cup gets activated as the drink is set down

A tray against the stop: its ring sits over the coil, the strip on the stop lights up.

Without a tray, the cup goes straight into the 1 mm dish.

Section: 3 mm cover, coil board over a ferrite sheet, the tag 4.65 mm above the coil.
Cover with locating dish
PC, frosted, 3 mm
injection moulded
14 g
Light guide ring and stop strip
PC, coral diffuse
moulded, bonded for the pilot
under 2 g
Housing and clamp nut
PA6 GF15, white
injection moulded
54 g
Coil board
FR4, two-turn 60 mm coil, 0.3 mm ferrite
PCB, ferrite laminated
Reader board
NFC front end, MCU, PoE
PCB assembly
Tray
existing tray with a moulded 2 mm ring
change to the tray tool
Cup
PP cup, NFC inlay under a welded cap
change to the cup tool, ultrasonic weld
44 g
I modelled the reader coil with the exact field of a circular loop and averaged it over the 25 mm tag. Small coils give a strong centre and a weak edge; large ones push a card laid on the spot over 7.5 A/m. A 60 mm coil with two turns at 188 mA keeps the tag between 5.9 and 7.9 A/m in every position the dish or the tray ring allows, and a card sees 4.2 A/m.
The read zone is a dome about 46 mm wide that ends 11.5 mm above the surface. The tag crosses 4.5 A/m only in the last centimetre of the move. The next cup on a tray, 90 mm away, sees about 0.1 A/m with the field reversed, so it is never read by mistake.
Steel 2 mm under the coil mirrors it with the opposite current and leaves 0.8 A/m at the tag. A ferrite sheet under the coil board turns the mirror around. With ferrite the field rises, so the drive is turned down and the matching tuned in place. Every installation ends with a read check using a reference cup.
Solution B
Signal strength cannot tell them apart
An empty cup 600 mm along the counter returns +5.8 dB, close to the +6.8 dB of the full cup in the gap.
What a fence would need
A read count over a time window, direction of travel from the two antennas and the lane check. Each one is tuned per counter, and steel and glass move the zone.
Where UHF fits
Wash hubs and stock counts, where reading many cups at once is the point.

NFC inlay, NTAG 213 type
ISO/IEC 14443 A
the spot, the return machine, a phone
centimetres
50 pF input capacitance, 100,000 writes (NXP). Chosen.
HF vicinity inlay
ISO/IEC 15693
dedicated readers
more than the spot needs
The extra reach works against a small, fixed zone.
UHF inlay, M800 type
RAIN RFID
fixed readers, tunnels
metres
-25.5 dBm read sensitivity (Impinj). Best for counting many cups at a wash hub.
Tag cost: €0.10 to €0.20 per cup for an NFC inlay in a welded foot, planning range. An in-mould label with the inlay, as Avery Dennison offers for UHF, would remove the weld; it needs a label robot on the cup mould.

The spot only reads. The order screen matches the read to an open order on that lane with a reusable cup on it, and only then asks the PackBack service to mark the cup active. A stray read with no matching order changes nothing.
If a reusable cup is still unread when the crew close the order, the screen asks for it. That check also helps the scanners already in the restaurants, so it goes live first.
Power
PoE from the store switch, one cable per spot, no batteries.
Network down
The spot keeps reads with lane and time and sends them when the network is back.
Feedback
Coral light and a short beep on a read; nothing on a stray read.
Concept comparison
Covers dine-in, takeaway and drive-thru
+
−
+
++
A only works for trays. C uses one spot per hand-out point and a carrier spot at the window.
Missed activations
+
+
+
++
Every option keeps the order-screen check for cups that never reach a reader; C needs no scan to get there.
Fit with the crew’s workflow
−
+
++
++
Scanning costs about 67 crew minutes per 1,000 drinks. A needs the exact tray spot.
Risk of false activation
++
++
−
++
B reads empty cups up to a metre away. A and C read 23 mm around the coil.
Hardware and installation
++
−
−
+
Per restaurant: A €3,000 to €5,400, B €1,840 to €3,680, C €285 to €485.
Robustness in daily use
+
−
0
+
Electronics in every tray against fixed readers on the counter.
Planning ranges from typical component, moulding and installation prices, not quotes: two hand-out points per restaurant and 60 trays. The tags add €100 to €200 per 1,000 NFC cups.



Cup
Mould the cup with the tag pocket
change to the existing cup tool: pocket, wall ring and cap recess
pocket dimensions
Cup
Place the inlay, weld the cap
pick and place, ultrasonic weld
leak test of the pocket, read test of every tag
Spot
Mould cover, light guide, housing and nut
four injection tools, PC and PA6 GF15
cover flatness, O-ring fit
Spot
Coil board and reader board
PCB assembly, ferrite sheet laminated under the coil
coil inductance and antenna current
Spot
Assemble, seal and tune
O-ring, clamp nut, matching network set
read test with a reference cup at 8.65 mm
Store
Install
90 mm hole and counterbore, one PoE cable
read check in place, steel counters retuned
A steel counter under the spot cuts the tag field to 0.8 A/m.
Ferrite sheet under the coil board, tuning in place, read check at install.
On a flat counter a cup outside the dish is read only within 23 mm of the centre.
Locating dish 1 mm deep, the moulded ring on trays, and the light tells the crew it worked.
Two reusable drinks on one tray: only the cup in the ring is read.
The second cup goes briefly into the dish, or a tray with two rings. The pilot decides.
A bank card or a phone laid on the spot.
4.2 A/m averaged over a card, under the 7.5 A/m limit. IDs that are not PackBack cups are ignored.
Spills and condensation on the spot.
Sealed cover with an O-ring and no openings on top; wipe-clean surface.
Tag damage in the tray wash.
Inlay enclosed under a welded cap; a 1,000-cycle wash test before release.
Network outage.
Reads stored with lane and time and sent later; the order-screen check still works.
Cups that never reach the spot.
The order screen asks for the cup before the order can be closed.
Read map on the bench
Does the field match the model?
Every position in the dish and the tray ring reads, in 5 mm steps, empty and full cups.
Stray-read check
Does anything else get read?
No read of a cup 90 mm away or of the clean stack over 1,000 set-downs.
Steel counter variant
Do ferrite and tuning recover the field?
The same read map as on laminate.
Wash test
Does the tag survive?
Every tag reads after 1,000 tray-wash cycles with an 82 to 90 °C rinse.
Store pilot, two restaurants, four weeks
Does it remove rejected returns?
Rejected returns for unactivated cups below 1 in 1,000, against the weeks before.
Crew time study
Does the crew save the scan?
No added time per order compared with orders without a reusable cup.
What I would do next
20 to 2
missed activations per 1,000 drinks with the order-screen check, at a 1 in 50 miss rate (model)
67 min
of scanning saved per 1,000 reusable drinks (model)
23 mm
read edge of the spot
€285 to €485
hardware per restaurant, planning range